VB001AM10 DOUBLE ANGLE BEAM-COLUMN VERTICAL BRACING CONNECTION

Vertical bracing transfer the lateral loads in the structure to the foundations. A well-designed vertical bracing system is critical to the stability of the structure. While there are different configurations for vertical bracing connections the calculations described in this section is for the double angle vertical bracing connections at beam-column junctions. The brace may frame into either the column flange or the column web.

vb001am10 support types

Validation record

The design checks performed by the program are verified against a series of manually performed calculations to verify the output. The complete validation document for this connection can be downloaded here.

Fit-up checks

The following checks for fit-up of the connection are performed by the program.

  • Checks for minimum bolt spacing as per AISC360.
  • Checks for minimum bolt edge distance at brace as per AISC360.
  • Checks for minimum bolt edge distance at gusset as per AISC360.
  • Checks for minimum bolt edge distance at clip angle as per AISC360.
  • Checks for minimum bolt edge distance on column flange as per AISC360.
  • Checks for bolt clash with brace fillet area.
  • Checks for bolt clash with clip fillet area.
  • Checks for bolt clash with column fillet area.
  • Checks for gusset clip angle clash with gusset to beam weld.
  • Checks for beam clip angle clash with beam fillet area.

Design checks

The following design checks are performed by the program.

  • Checks for brace rupture
  • Checks for bolt shear at brace
  • Checks for bolt bearing at brace
  • Checks for bolt bearing at gusset
  • Checks for brace block shear
  • Checks for gusset plate block shear
  • Checks for gusset tension yielding
  • Checks for gusset tension rupture
  • Checks for gusset plate compression buckling
  • Checks for bolt shear at beam to column connection
  • Checks for bolt bearing on clip at beam to column connection
  • Checks for bolt bearing on flange at beam to column connection
  • Checks for weld at beam to column connection
  • Checks for web rupture at beam to column connection weld
  • Checks for bolt tension at beam to column connection
  • Checks for clip angle prying at beam to column connection
  • Checks for clip shear yielding at beam to column connection
  • Checks for clip shear rupture at beam to column connection
  • Checks for clip block shear at beam to column connection
  • Checks for flange prying at beam to column connection
  • Checks for column web yielding at beam to column connection
  • Checks for column web crippling at beam to column connection
  • Checks for column web shear at beam to column connection
  • Checks for weld at gusset to beam connection
  • Checks for gusset rupture at gusset to beam connection
  • Checks for local web yielding at gusset to beam connection
  • Checks for local web crippling at gusset to beam connection
  • Checks for web shear at gusset to beam connection
  • Checks for bolt shear at gusset to column connection
  • Checks for bolt bearing on clip at gusset to column connection
  • Checks for bolt bearing on column at gusset to column connection
  • Checks for bolt tension at gusset to column connection
  • Checks for clip angle prying at gusset to column connection
  • Checks for weld at gusset to column connection
  • Checks for gusset rupture at gusset to column connection weld
  • Checks for block shear at gusset to column connection clip
  • Checks for clip shear yielding at gusset to column connection
  • Checks for clip shear rupture at gusset to column connection
  • Checks for flange prying at gusset to column connection
  • Checks for column web yielding at gusset to column connection
  • Checks for column web crippling at gusset to column connection

Assumptions in design

The following assumptions are made while performing the design of the connection.

  • The forces in the connection are calculated using the Uniform Force Method (UFM)
  • Beam forces and UFM forces are conservatively considered additive.
  • The gusset plate is designed in tension assuming a 30deg dispersion angle or as is also known, the “Whitmore section”.
  • Compression in the gusset plate is checked using an average unsupported buckling length calculated at three points: along the centreline of the brace and at the corners of the “Whitmore section” as described above.
  • Osoconn also does not check gusset edge buckling. To prevent this mode of failure it is advised to provide stiffener plates or angles near the gusset edge when the free edge length becomes excessive.
  • Bearing check assumes deformation at bolt hole is a service consideration.
  • Local web crippling check conservatively assumes that the connection is near the edge of the column.

Input parameters

The input file for this connection requires the following parameters to run.

ParameterAcceptable valueExample
CONNECTION_CODEVB001AM10CONNECTION_CODE VB001AM10
CONNECTION_IDAny alpha-numeric set of characters used to identify the connection.CONNECTION_ID VERT_BR_54
METHODASD|LRFDMETHOD ASD
UNITSNEWTON_MM|KIP_INUNITS NEWTON_MM
MODULUS_OF_ELASTICITYA positive number.MODULUS_OF_ELASTICITY 200000
ANGLE_GRADEA36|A992ANGLE_GRADE A36
BEAM_GRADEA36|A992BEAM_GRADE A992
COLUMN_GRADEA36|A992COLUMN_GRADE A992
PLATE_GRADEA36PLATE_GRADE A36
WELD_ELECTRODEE70WELD_ELECTRODE E70
BOLT_GRADEA325|A490BOLT_GRADE A325
BRACE_FORCEA numeric value.BRACE_FORCE 750000
BEAM_SHEAR_FORCEA numeric value.BEAM_SHEAR_FORCE 30000
BEAM_TRANSFER_FORCEA numeric value.BEAM_TRANSFER_FORCE 15000
BEAM_SECTIONA valid AISC W-sectionBEAM_SECTION W14x53
BRACE_SECTIONA valid AISC angle sectionBRACE_SECTION L102X102X9.5
COLUMN_SECTIONA valid AISC W-sectionCOLUMN_SECTION W14x82
GUSSET_THICKNESSA positive number.GUSSET_THICKNESS 16
BOLT_DIAMETERIf unit is set to NEWTON_MM:
M16|M20|M22|M24|M27|M30|M36.
If unit is set to KIP_IN:
1/2|5/8|3/4|7/8|1|1_1/8|1_1/4|1_3/8|1_1/2.
BOLT_DIAMETER M22
BOLT_TYPEBEARING|FRICTIONBOLT_TYPE BEARING
THREAD_INCLUDED_IN_SHEARYES|NOTHREAD_INCLUDED_IN_SHEAR YES
FAYING_SURFACECLASS_A|CLASS_BFAYING_SURFACE CLASS_A
BOLT_GAGEA positive number.BOLT_GAGE 140
BOLT_GAGE_ON_BRACEA positive number.BOLT_GAGE_ON_BRACE 45
BOLT_SPACINGA positive number.BOLT_SPACING 70
EDGE_DISTANCE_ON_BRACEA positive number.EDGE_DISTANCE_ON_BRACE 35
EDGE_DISTANCE_ON_GUSSETA positive number.EDGE_DISTANCE_ON_GUSSET 35
EDGE_DISTANCE_ON_CLIPA positive number.EDGE_DISTANCE_ON_CLIP 35
NUMBER_OF_BOLTS_PER_ROW_ON_BRACEAn integer value greater or equal to 2.NUMBER_OF_BOLTS_PER_ROW_ON_BRACE 5
NUMBER_OF_BOLT_ROWS_ON_BRACE1|2NUMBER_OF_BOLT_ROWS_ON_BRACE 1
BOLT_ROW_SPACINGA positive number.BOLT_ROW_SPACING 60
BRACE_ANGLEA numeric value between 20 and 80 inclusive.BRACE_ANGLE 35
BRACE_OUTSTANDING_LEGLONG_LEG|SHORT_LEGBRACE_OUTSTANDING_LEG LONG_LEG
BRACE_DIST_FROM_WPA positive number.BRACE_DIST_FROM_WP 800
GUSSET_TO_BEAM_WELDA positive number.GUSSET_TO_BEAM_WELD 8
GUSSET_LENGTHA positive number.GUSSET_LENGTH 450
SUPPORT_TYPECOLUMN_FLANGE|COLUMN_WEBSUPPORT_TYPE COLUMN_FLANGE
CLIP_SECTIONA valid AISC angle sectionCLIP_SECTION L127X76X12.7
CLIP_OUTSTANDING_LEGLONG_LEG|SHORT_LEGCLIP_OUTSTANDING_LEG LONG_LEG
NUMBER_OF_BOLTS_GUSSET_CLIPAn integer value greater or equal to 2.NUMBER_OF_BOLTS_GUSSET_CLIP 5
NUMBER_OF_BOLT_BEAM_CLIPAn integer value greater or equal to 2.NUMBER_OF_BOLT_BEAM_CLIP 3
CLIP_ANGLE_WELD_THICKNESSA positive number.CLIP_ANGLE_WELD_THICKNESS 6
GUSSET_CLIP_LOCATIONA positive number.GUSSET_CLIP_LOCATION 50
CONNECTION_SETBACKA positive number.CONNECTION_SETBACK 12